Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Tex Heart Inst J ; 50(6)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38073437

RESUMO

Left ventricular pseudoaneurysm with a left-to-right shunt is extremely rare, requiring surgery if symptomatic; however, surgery has a high risk. Here, the case of a 77-year-old man with heart failure symptoms is reported, in which he develops a giant left ventricular pseudoaneurysm 16 months after ventricular septal perforation repair as a result of acute myocardial infarction, with mild shunt blood flow from the pseudoaneurysm to the right ventricle. Intraoperative findings showed a free wall rupture along the area where the patch was secured during the initial surgery. The patient was discharged on postoperative day 13, and postoperative examination revealed no abnormalities.


Assuntos
Falso Aneurisma , Aneurisma Cardíaco , Infarto do Miocárdio , Ruptura do Septo Ventricular , Masculino , Humanos , Idoso , Ruptura do Septo Ventricular/diagnóstico por imagem , Ruptura do Septo Ventricular/etiologia , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/etiologia
2.
J Tehran Heart Cent ; 18(2): 142-145, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37637275

RESUMO

Coronary artery aneurysms (CAAs) occur when an artery dilates 1.5 times the reference vessel. They occur most commonly because of atherosclerosis. CAAs are a rare phenomenon, and it is even rarer to find a giant CAA, which is roughly defined as a size 400% above the reference vessel. Giant CAAs are commonly found in the right coronary artery. The sinoatrial nodal artery (SNA) is among the least common sites for CAA involvement. Sometimes, communication exists between the aneurysm and a chamber of the heart or a great vessel. The consequences of the fistula depend on its size. Because of the rarity of the condition, guidelines are not well developed. However, small CAAs can be managed conservatively, whereas giant CAAs require resection, ligation, and bypass grafting. CAAs have a predilection for males and the elderly. We describe a 40-year-old South Asian woman presenting with mild dyspnea on exertion of 1 year's duration. Echocardiography showed a 60×60 mm cystic sac, subsequently confirmed by computerized tomography, which showed 3 large aneurysms (70×61 mm) and 3 small aneurysms in the SNA. Coronary angiography illustrated that the SNA branched off the left main coronary artery, and the aneurysm communicated with the right coronary artery. The aneurysm was partially resected and plicated.

3.
Tex Heart Inst J ; 50(2)2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-37011364

RESUMO

Although the management of traumatic injuries to the thoracic aorta has shifted toward endovascular management, the historical standard of care is open reconstruction. Choosing to reoperate when faced with a complication from a prior open repair can be challenging; endovascular management can be a reasonable option in this situation. This report describes a 54-year-old man with a remote history of open surgery for a traumatic injury to the descending thoracic aorta who underwent endovascular aortic stent graft placement for coverage of extrathoracic graft extension with pseudoaneurysm formation and distal embolization. He returned a year later with a type IIIb endoleak with rupture into the posterolateral chest wall. A sec ond endovascular approach was used to successfully reline the graft and exclude the rupture.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Ferimentos por Arma de Fogo , Masculino , Humanos , Pessoa de Meia-Idade , Ferimentos por Arma de Fogo/complicações , Ferimentos por Arma de Fogo/diagnóstico , Ferimentos por Arma de Fogo/cirurgia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Implante de Prótese Vascular/efeitos adversos , Stents/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Prótese Vascular/efeitos adversos , Resultado do Tratamento , Complicações Pós-Operatórias
4.
Br J Neurosurg ; 37(4): 904-906, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31994916

RESUMO

We report a case of coil migration into the oropharynx five years after treatment of a left internal carotid pseudoaneurysm following abandoned transsphenoidal resection of a pituitary macroadenoma. Eight other cases were found on literature review, with coil migration occurring between 2 and 120 months often after a history of transsphenoidal surgery. The majority of these were treated with trimming in a day case setting. This report highlights the need for careful extended follow up when a pseudoaneurysm forms with a concurrent skull base deficit.


Assuntos
Falso Aneurisma , Lesões das Artérias Carótidas , Embolização Terapêutica , Neoplasias Hipofisárias , Humanos , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/cirurgia , Lesões das Artérias Carótidas/etiologia , Neoplasias Hipofisárias/diagnóstico por imagem , Neoplasias Hipofisárias/cirurgia , Neoplasias Hipofisárias/complicações , Embolização Terapêutica/efeitos adversos
5.
Dig Dis Sci ; 68(5): 1959-1965, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36478315

RESUMO

BACKGROUND: Left gastric artery (LGA) pseudoaneurysm presenting with upper gastrointestinal (UGI) bleeding is rare but fatal, unless treated. AIMS: We aimed to describe the clinical and endoscopic features of patients with UGI bleeding due to LGA pseudoaneurysms. METHODS: We performed a computerized search of our hospital's de-identified clinical data warehouse to identify patients with UGI bleeding due to an LGA pseudoaneurysm between 2000 and 2020. Patients' electronic medical records and data on esophagogastroduodenoscopy and digital subtraction angiography were reviewed retrospectively. RESULTS: Of 26 patients with an LGA pseudoaneurysm, six patients had UGI bleeding related to an LGA pseudoaneurysm. No patients had previous vascular diseases or pancreatitis. One patient had liver cirrhosis and a history of radiofrequency ablation for hepatocellular carcinoma, one had colon cancer, two had undergone abdominal surgeries, one had received chemoradiotherapy for renal cell carcinoma, and one had no intraabdominal diseases. Symptoms were hematemesis in two, hematochezia in the other two, and melena in the remaining two patients. Esophagogastroduodenoscopy showed a pulsating bulge in the ulcer in two and a large Dieulafoy's lesion-like structure in four patients. All patients achieved hemostasis by angioembolization. CONCLUSION: LGA pseudoaneurysm should be suspected in UGI bleeding if a large Dieulafoy's lesion-like structure or a pulsating bulge in the ulcer is found at the lesser curvature of the gastric body on endoscopy and if the patient has any intra-abdominal inflammatory disease.


Assuntos
Falso Aneurisma , Gastroenteropatias , Humanos , Falso Aneurisma/complicações , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/terapia , Artéria Gástrica/diagnóstico por imagem , Estudos Retrospectivos , Úlcera , Hemorragia Gastrointestinal/diagnóstico , Endoscopia Gastrointestinal
6.
J. Transcatheter Interv ; 31: eA202301, 2023.
Artigo em Inglês, Português | LILACS-Express | LILACS | ID: biblio-1527158

RESUMO

A abordagem transradial é indicada para reduzir risco de morte, complicações vasculares ou sangramento. Em pacientes com doença cardíaca isquêmica estável, a abordagem radial é recomendada para diminuir sangramento no local de acesso e complicações vasculares. As complicações são raras, podendo ocorrer hematoma, perfuração e, muito raramente, pseudoaneurisma da artéria radial. Neste relato de caso, é descrito um caso raro de pseudoaneurisma da artéria radial esquerda associada à síndrome compartimental no antebraço esquerdo após realização de cateterismo eletivo. O diagnóstico foi confirmado por ultrassonografia com Doppler, que evidenciou pseudoaneurisma da artéria radial esquerda, medindo 2,1x1,5cm, com colo de 0,3cm. O tratamento cirúrgico do pseudoaneurisma e da síndrome compartimental restaurou a função completa do membro.


The transradial approach is indicated to reduce the risk of death, vascular complications, or bleeding. In patients with stable ischemic heart disease, the radial approach is recommended to reduce vascular complications and bleeding on access site. The complications are rare, and hematoma, perforation, and pseudoaneurysm (very rarely) of the radial artery may occur. This case report describes a rare case of left radial artery pseudoaneurysm associated with compartment syndrome in the left forearm after elective catheterization. The diagnosis was confirmed by Doppler ultrasonography, which showed a left radial artery pseudoaneurysm, measuring 2.1x1.5cm, with a 0.3-cm long/wide neck. Surgical treatment of pseudoaneurysm and compartment syndrome restored full limb function.

7.
Taehan Yongsang Uihakhoe Chi ; 83(1): 189-193, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36237349

RESUMO

Hemorrhage after pancreaticobiliary surgery is an infrequent but fatal complication. It is primarily caused by rupture of the pseudoaneurysm, and treatment options include endovascular coil embolization or endovascular stent-graft placement. Herein, we report a case of migration of an arterial stent-graft that was placed in the common hepatic artery to treat pseudoaneurysm after pylorus-preserving pancreaticoduodenectomy. The stent-graft migrated to the jejunum and was eventually excreted from the body.

8.
Rev. gastroenterol. Peru ; 42(4)oct. 2022.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1423952

RESUMO

Presentamos el caso de un varón de 64 años quien, tras un primer episodio de pancreatitis aguda necrotizante, reingresa a los 20 días por cuadro de dolor epigástrico intenso y posteriormente episodio de hemorragia digestiva alta en forma de hematemesis y melenas con inestabilización hemodinámica. Se realiza en ese momento gastroscopia urgente objetivándose probable fistula gastrointestinal en bulbo duodenal con coágulo adherido sin sangrado activo en ese momento por lo que se realiza angio-TC urgente que revela colección peripancreática necrótica con presencia de sangrado activo en su interior, procedente de la arteria pancreatoduodenal. La arteriografía urgente identificó imagen compatible con pseudoaneurisma arterial dependiente de la rama de arteria pancreatoduodenal, que fue embolizada con éxito. Desgraciadamente el paciente falleció en las horas posteriores, como consecuencia de un shock séptico secundario a colección pancreática infectada.


We present the case of a 64-year-old man who, after a first episode of acute pancreatitis, was readmitted 20 days later due to severe epigastric pain and later an episode of upper gastrointestinal bleeding in the form of hematemesis and melena with hemodynamic instability. An urgent gastroscopy was performed at that time, revealing a probable gastrointestinal fistula in the duodenal bulb with an adherent clot without active bleeding at that time, so an urgent CT angiography was performed that revealed a necrotic peripancreatic collection with the presence of active bleeding inside from the pancreatoduodenal artery. Urgent arteriography identified an image compatible with arterial pseudoaneurysm dependent on the pancreaticoduodenal artery branch, which was successfully embolized. Unfortunately, the patient died a few hours later as a result of septic shock secondary to an infected pancreatic collection.

10.
Rev. bras. cir. cardiovasc ; 36(2): 261-264, Mar.-Apr. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1251106

RESUMO

Abstract Pseudoaneurysm of the ascending aorta (PAA) is a hazardous and potentially fatal cardiovascular disease. This condition is caused by the rupture of at least one layer of the vessel and contained by the remaining vascular layers or the surrounding mediastinal structures. We presented the surgical treatment of a patient with sepsis and large PAA and brachiocephalic trunk, which was compressing the brachiocephalic trunk leading to syncope.


Assuntos
Humanos , Falso Aneurisma/cirurgia , Falso Aneurisma/diagnóstico por imagem , Sepse/complicações , Aorta/cirurgia , Tronco Braquiocefálico/cirurgia , Tronco Braquiocefálico/diagnóstico por imagem
11.
Int. braz. j. urol ; 47(1): 149-158, Jan.-Feb. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1134310

RESUMO

ABSTRACT Purpose: Renal artery pseudoaneurysms (RAPs) and arteriovenous fistulas (AVFs) are rare but potentially life-threatening complications after partial nephrectomy (PN). Selective arterial embolization (SAE) is an effective method for controlling RAPs/AVFs. We assessed the clinical factors affecting the occurrence of RAPs/AVFs after PN and the effects of SAE on postsurgical renal function. Materials and Methods: Four hundred ninety-three patients who underwent PN were retrospectively reviewed. They were placed in either the SAE or the non-SAE group. The effects of clinical factors, including R.E.N.A.L. scores, on the occurrence of RAPs/AVFs were analyzed. The influence of SAE on the estimated glomerular filtration rate (eGFR) during the first postoperative year was evaluated. Results: Thirty-three (6.7%) patients experienced RAPs/AVFs within 8 days of the median interval between PN and SAE. The SAE group had significantly higher R.E.N.A.L. scores, higher N component scores, and higher L component scores (all, p <0.05). In the multivariate analysis, higher N component scores were associated with the occurrence of RAPs/AVFs (Odds ratio: 1.96, p=0.039). In the SAE group, the mean 3-day postembolization eGFR was significantly lower than the mean 3-day postoperative eGFR (p <0.01). This difference in the eGFRs was still present 1 year later. Conclusions: Renal tumors located near the renal sinus and collecting system were associated with a higher risk for RAPs/AVFs after PN. Although SAE was an effective method for controlling symptomatic RAPs/AVFs after PN, a procedure-related impairment of renal function after SAE could occur and still be present at the end of the first postoperative year.


Assuntos
Humanos , Fístula Arteriovenosa/etiologia , Falso Aneurisma/etiologia , Neoplasias Renais/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Taxa de Filtração Glomerular , Nefrectomia/efeitos adversos
12.
Int Braz J Urol ; 47(1): 149-158, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33047920

RESUMO

PURPOSE: Renal artery pseudoaneurysms (RAPs) and arteriovenous fistulas (AVFs) are rare but potentially life-threatening complications after partial nephrectomy (PN). Selective arterial embolization (SAE) is an effective method for controlling RAPs/AVFs. We assessed the clinical factors affecting the occurrence of RAPs/AVFs after PN and the effects of SAE on postsurgical renal function. MATERIALS AND METHODS: Four hundred ninety-three patients who underwent PN were retrospectively reviewed. They were placed in either the SAE or the non-SAE group. The effects of clinical factors, including R.E.N.A.L. scores, on the occurrence of RAPs/AVFs were analyzed. The influence of SAE on the estimated glomerular filtration rate (eGFR) during the first postoperative year was evaluated. RESULTS: Thirty-three (6.7%) patients experienced RAPs/AVFs within 8 days of the median interval between PN and SAE. The SAE group had significantly higher R.E.N.A.L. scores, higher N component scores, and higher L component scores (all, p <0.05). In the multivariate analysis, higher N component scores were associated with the occurrence of RAPs/AVFs (Odds ratio: 1.96, p=0.039). In the SAE group, the mean 3-day postembolization eGFR was significantly lower than the mean 3-day postoperative eGFR (p <0.01). This difference in the eGFRs was still present 1 year later. CONCLUSIONS: Renal tumors located near the renal sinus and collecting system were associated with a higher risk for RAPs/AVFs after PN. Although SAE was an effective method for controlling symptomatic RAPs/AVFs after PN, a procedure-related impairment of renal function after SAE could occur and still be present at the end of the first postoperative year.


Assuntos
Falso Aneurisma , Fístula Arteriovenosa , Neoplasias Renais , Falso Aneurisma/etiologia , Fístula Arteriovenosa/etiologia , Taxa de Filtração Glomerular , Humanos , Neoplasias Renais/cirurgia , Nefrectomia/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
13.
Braz J Cardiovasc Surg ; 36(2): 261-264, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33355802

RESUMO

Pseudoaneurysm of the ascending aorta (PAA) is a hazardous and potentially fatal cardiovascular disease. This condition is caused by the rupture of at least one layer of the vessel and contained by the remaining vascular layers or the surrounding mediastinal structures. We presented the surgical treatment of a patient with sepsis and large PAA and brachiocephalic trunk, which was compressing the brachiocephalic trunk leading to syncope.


Assuntos
Falso Aneurisma , Sepse , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Aorta/cirurgia , Tronco Braquiocefálico/diagnóstico por imagem , Tronco Braquiocefálico/cirurgia , Humanos , Sepse/complicações
14.
Radiol. bras ; 53(6): 390-396, Nov.-Dec. 2020. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1136116

RESUMO

Abstract Objective: To identify the main hemorrhagic complications after percutaneous nephrolithotomy, as well as the results obtained with transcatheter arterial embolization (TAE) at an interventional radiology center. Materials and Methods: This was a retrospective analysis of patients undergoing TAE for the treatment of hemorrhagic complications after percutaneous nephrolithotomy. All patients underwent computed tomography angiography (CTA). Results: We evaluated a total of nine patients. At emergency department readmission, the most common symptom was macroscopic hematuria, which was seen in five patients. Three patients had an isolated pseudoaneurysm, two had a pseudoaneurysm together with active bleeding (perirenal hematoma), and one had a pseudoaneurysm together with arteriocalyceal fistula. Arteriovenous fistula was diagnosed in three patients and was not seen in combination with other vascular lesions. We did not identify arteriocalyceal fistula in isolation. Five patients underwent TAE with 6 × 15 mm and 6 × 20 mm microcoils. Four patients underwent TAE with n-butyl-2-cyanoacrylate and ethiodized oil. Follow-up CTAs revealed no complications. Conclusion: Because of its high diagnostic accuracy, CTA provides the interventional radiologist with valuable data for individualized therapeutic planning. The TAE procedure is safe and effective. It can therefore be used as a first-line treatment for hemorrhagic complications resulting from percutaneous renal procedures.


Resumo Objetivo: Demonstrar as principais complicações hemorrágicas após nefrolitotripsia percutânea, bem como os resultados após o tratamento por embolização arterial transcateter (EAT) em um centro de radiologia intervencionista. Materiais e Métodos: Coleta e análise de dados retrospectivos de pacientes submetidos a EAT por complicações hemorrágicas após nefrolitotripsia percutânea. Resultados: O sintoma mais comum foi hematúria macroscópica, presente em cinco pacientes no momento da readmissão ao pronto-socorro, e nestes pacientes identificamos três pseudoaneurismas isolados, dois casos de combinação de pseudoaneurisma e sangramento ativo (hematoma perirrenal) e um caso de associação de pseudoaneurisma e fístula arteriocalicinal. Fístula arteriovenosa foi diagnosticada em três pacientes, não sendo observada em associação com outras lesões vasculares. Não identificamos fístula arteriocalicinal isolada, somente associada a pseudoaneurisma. Cinco pacientes foram submetidos a embolização por micromolas 6 × 15 mm e 6 × 20 mm. Quatro pacientes foram submetidos a embolização por Histoacryl e Lipiodol. Não observamos complicações pela angiotomografia computadorizada de controle. Conclusão: A angiotomografia computadorizada apresenta alta acurácia diagnóstica e guarnece o radiologista intervencionista de dados para um planejamento terapêutico individualizado. EAT é um procedimento seguro e eficaz e pode ser utilizado como primeira linha para o tratamento de complicações hemorrágicas resultantes de procedimentos percutâneos renais.

15.
Horiz. méd. (Impresa) ; 20(4): e917, oct-dic 2020. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1339995

RESUMO

RESUMEN Se presenta el caso de un varón de 46 años, asintomático y con antecedente de prótesis mecánica aórtica monodisco desde hace 25 años. Mediante el empleo de la ecocardiografía transtorácica, ecocardiografía transesofágica y tomografía cardiaca, se le diagnostica, incidentalmente, un pseudoaneurisma de la fibrosa intervalvular mitroaórtica (región de tejido fibroso localizada entre el velo anterior de la válvula mitral y los velos aórticos izquierdo y no coronariano). Debido al tamaño del pseudoaneurisma, se decide realizar una cirugía. Este artículo muestra la presentación tardía de un pseudoaneurisma en esta localización que aparece como una complicación del reemplazo de la válvula aórtica por endocarditis. Se destaca la evolución asintomática, el tamaño y la cirugía que preserve la válvula cuando no está comprometida. Las diferentes técnicas de imagen son complementarias y ayudan en tomar las decisiones del caso.


ABSTRACT This is the case of a 46-year-old man, asymptomatic, with a history of single-disk mechanical aortic prosthesis implanted 25 years ago, who was incidentally diagnosed with a pseudoaneurysm of the mitral-aortic intervalvular fibrosa (a region of fibrous tissue located between the anterior leaflet of the mitral valve and the left and non-coronary aortic leaflets) discovered by means of a transthoracic echocardiography, transesophageal echocardiography and cardiac computed tomography. Surgery was decided because of the size of the pseudoaneurysm. This article shows the late presentation of a pseudoaneurysm in this location caused by a complication of an aortic valve replacement due to endocarditis. It also highlights the asymptomatic evolution, the size of the pseudoaneurysm and the election of a valve preserving surgery because the valve was not compromised. The different imaging techniques are complementary to the research and help to make the pertinent decisions.

16.
Tex Heart Inst J ; 47(2): 149-151, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32603467

RESUMO

Successful surgical repair of aortic coarctation during childhood may have major late complications such as pseudoaneurysm formation. If left untreated, pseudoaneuryms put patients at risk for morbidity and death; if treated surgically, they are associated with complications. Endovascular aortic repair, an established safe alternative to open surgical repair, is associated with encouraging outcomes and fewer complications, and it is especially feasible for patients who have undergone multiple aortic surgeries. We report the case of a 41-year-old man who underwent endovascular repair of a pseudoaneurysm after previous surgical corrections of an aortic coarctation at 6 and 14 years of age. The pseudoaneurysm, involving the distal portion of an ascending-to-descending aortic 20-mm Dacron bypass graft, was successfully excluded with a thoracic stent-graft and sealed off with vascular plugs to prevent both blood flow into the pseudoaneurysm and type II endoleak.


Assuntos
Falso Aneurisma/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Coartação Aórtica/cirurgia , Prótese Vascular , Procedimentos Endovasculares/métodos , Adulto , Falso Aneurisma/diagnóstico , Falso Aneurisma/etiologia , Coartação Aórtica/diagnóstico , Aortografia , Angiografia por Tomografia Computadorizada , Humanos , Masculino , Reoperação
17.
Internist (Berl) ; 61(5): 513-517, 2020 May.
Artigo em Alemão | MEDLINE | ID: mdl-32246182

RESUMO

This article presents the case of a 75-year-old male patient, who underwent a percutaneous abscess puncture of a liver abscess. A few days after the puncture and drainage there was a sudden onset of right upper quadrant abdominal pain accompanied by hematochezia. The patient presented with markedly elevated liver enzyme levels and a significant drop in hemoglobin concentration. After gastroscopy and abdominal computed tomography (CT) in the portal venous phase no bleeding source could be identified. A false aneurysm of the cystic artery was identified only after a CT angiography of the abdomen. Due to spontaneous cessation of the bleeding a cholecystectomy was subsequently performed for definitive treatment of the false aneurysm.


Assuntos
Dor Abdominal/etiologia , Aneurisma/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Hemorragia Gastrointestinal/etiologia , Artéria Hepática/diagnóstico por imagem , Abscesso Hepático/cirurgia , Punções/efeitos adversos , Idoso , Aneurisma/cirurgia , Colecistectomia , Drenagem , Artéria Hepática/cirurgia , Humanos , Masculino , Resultado do Tratamento
19.
Taehan Yongsang Uihakhoe Chi ; 81(4): 953-957, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36238184

RESUMO

We present a rare case demonstrating successful endovascular management of an arterioureteral fistula involving the abdominal aorta. Arterioureteral fistulas are rare but life-threatening, with mortality rates ranging from 7% to 23%. Early recognition and prompt management are essential for preventing catastrophic consequences, including hypovolemic shock. However, recognition of an arterioureteral fistula requires a high index of clinical suspicion due to its rarity and the lack of a sensitive diagnostic method. Arterioureteral fistulas could be induced by traumatic events in patients who have a history of pelvic surgery, radiation, and prolonged placement of a ureteral stent. Endovascular stent graft placement could be a valid treatment option for arterioureteral fistulas involving the abdominal aorta.

20.
J Tehran Heart Cent ; 15(3): 131-135, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33552209

RESUMO

Behçet's disease (BD) is a multisystem inflammatory disorder. Physicians should be alerted to the possibility of BD in a patient with a carotid artery pseudoaneurysm and no clear predisposing factor such as neck trauma or surgery. Endovascular repair of carotid pseudoaneurysms is technically feasible with excellent midterm follow-up results. Administration of immunosuppressive therapy before endovascular intervention is mandatory to reduce the chance of vascular complications accompanied by BD. A 40-year-old man presented with a painful and pulsatile neck mass with 2 episodes of transient ischemic attacks. The patient also complained of recurrent urogenital ulcers and aphthous lesions together with painful rashes. Ultrasonography and computed tomography angiography revealed 2 aneurysmal dilations in the left common carotid artery at the bifurcation level. He was referred to a rheumatologist, who made the diagnosis of BD. High-dose corticosteroids and cyclophosphamide were commenced. One week later, 2 overlapping self-expanding stent grafts were deployed. The final angiogram showed no residual endoleak, and the flow of the carotid and cerebral arteries was satisfactory. The patient was discharged with no neurological complications. Follow-up ultrasonography and computed tomography angiography 6 months later showed no endoleak, as well as significant shrinkage of the aneurysm sac.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA